ITYS ES 1000-3000VA “online double conversion” for electrical substations

 

 

 

 

 

 

Manual bypass (option)

Specially designed for ITYS ES, the manual bypass option enables:

• simplified installation: connection to the system is made with industrial grade terminals, while connection to the UPS is via the pre-wired plug and socket supplied.

• easy maintenance and uninterrupted operation: thanks to the manual bypass isolator it is possible to service or replace the UPS while maintaining the power supply to the devices downstream in complete safety for the operator. This operation has been specially devised to be simple to carry out, even in an emergency.

• increased level of equipment immunity to surge voltages, typical for this type of application, thanks to suitable surge arrestors included in addition to standard UPS protection.
  itys_025_a_101x120.jpg

 

Programmable clean contacts board (option)

 

Dedicated interface with clean contacts, can be installed on the rear slot: gives the status of the UPS with five potential-free contacts and provides an input for remote emergency stopping (EPO).

itys_023_a_108x80.jpg

  itys_024_a_gb_370x223.png

 

Rear view connections

itys_es_raccordements.png

1. Fan

2. Slot for optional communication boards

3. RS232 serial port (JBUS protocol)

4. Telephone / modem / ASDL line protection

5. Output sockets (IEC 320)

6. Input socket (IEC 320)

7. Manual bypass

8. Input protection (Thermal breaker)

9. Output terminals

10. Connection for external battery cabinet (LB models only)

 

 

Technical data

 

  ITYS ES - UPS
Sn 1000 VA 2000 VA 3000 VA
Pn 800 W 1600 W 2400 W
Input / output 1/1
Input
Rated voltage 230 V (110÷300 V)
Rated frequency 50/60 Hz
Power factor 0.98
Output
Rated voltage 208 / 220 / 230 / 240 V (± 2 %)
Rated frequency 50 / 60 Hz (45÷55 Hz / 54÷66 Hz)
Overload up to 150 % for 10 seconds
Crest factor 3:1
Connections 3 x IEC 320

(C13)
6 x IEC 320

(C13)
4 x IEC 320

(C13) + terminals
Batteries
Type sealed lead-acid maintenance free - expected lifetime 3-5 years
Back-up time at 75% of the rated load(1) 10 min 17 min 9 min
Sized for a back-up time of 115 min @ 50 W 154 min @ 100 W 216 min @ 150 W
Back-up time(2) + switching back on 60 min @ 50 W 60 min @ 100 W 60 min @ 150 W
Battery test
Communication
Interfaces RS232 - USB
Ethernet adapter NET VISION (TCP / IP & SNMP) optional card
Local communication software Local View
Efficiency
Online mode up to 92%
Environment
Ambient service temperature 0 °C to +40 °C (15 °C to 25 °C for maximum battery lifetime)
Relative humidity < 95% non-condensing
Maximum altitude 1000 m without de-rating
Noise level at 1 m < 50 dBA
UPS cabinet
Dimensions W x D x H 145 x 400 x 220 mm 192 x 460 x 350 mm
Weight 13 kg 31 kg 60 kg
Degree of protection IP20
Standards
Safety IEC/EN 62040-1, AS 62040.1.1, AS 62040.1.2
EMC IEC/EN 62040-2, AS 62040.2
Product certification CE, RCM (E2376)

 

  ITYS ES - Manual bypass(3)
Sn 1000 VA 2000 VA 3000 VA
Input
Type of terminals CBD6
Wire size 6 mm2 max
Bypass
Switching positions 1: UPS - 2: MAINS
Switching time 6 ms max
Load output
Type of terminals CBD6
Wire size 6 mm2 max
UPS supply output
Type of socket IEC 320 10 A IEC 320 16 A
Surge arrestors (on request)
Type “L” in compliance with CEI EN 61643-11
L/N pulse current 40 kA (8/20) max
VAC N/GND 255 V max
VAC L/N 320 V max

(1) @ 25 °C with charged battery.

(2) Factory setting: back-up time limited to 60 minutes to permit subsequent restarting with battery.  

(3) Upon request.